- Extended bandwidth, extremely smooth frequency response.
- 110° x 85° HF coverage, rotatable horn.
- 110 W transformer for 70 V or 100 V lines, with 8 ohm thru.
- SonicGuard™ overload protection.
- 200 mm (8 in) Kevlar cone woofer,
25 mm (1 in) titanium diaphragm compression driver. - Includes InvisiBall™ mounting hardware, plus ten 6 mm attachment points for suspension and
optional U-bracket. - Sealed input panel cover and screwdown input terminals.
Specifications
Frequency Range | 37 Hz –18 kHz (-10 dB) |
Power Capacity | 300 W Continuous Program Power; 150 W Continuous Pink Noise |
Transformer Taps | 70 V: 110 W, 55 W, 28 W & 14 W 100 V: 110 W, 55 W, & 28 W, Thru Position: 8 ohms nominal |
Frequency Response | 45 Hz – 18 kHz ( ± 3 dB) |
Maximum SPL (1m) | Short-Term: 120 dB; Long-Term: 114 dB |
Nominal Sensitivity | 90 dB (2.83V / 1m) |
Coverage Angle | 110° H x 85° V, rotatable |
Directivity Factor (Q) | 7.2 dB, averaged 500 Hz to 16 kHz |
Directivity Index (DI) | 8.6 dB, averaged 500 Hz to 16 kHz |
Impedance | 8 ohms |
Minimum Impedance | 6.3 ohms @ 230 Hz |
Crossover Network | 3rd order High Pass, 2nd order Low Pass with impedance compensation, 2.5 kHz crossover frequency |
Drivers | LF: 200 (8 in) kevlar cone with pure butyl rubber surround, 50 mm (2 in) voicecoil on fiberglass former HF: 25 mm (1 in) compression driver, pure titanium diaphragm with patented JBL diamond surround |
Enclosure | High impact polystyrene |
Grille | Thermoset composite coated steel, WeatherMax multi-layer foam |
Overload Protection | Full-range power limiting to protect network and transducers. Serviceable internal fuse to protect during exceptional overload conditions. |
Outdoor Capability | IEC 529 IP-X4 rating. Exceeds Mil Spec 810 for humidity, salt spray, temperature & UV. Passes Mil-Std-202F for salt spray. |
Input Connectors | Screw-down terminal strip, zinc plated copper base, nickel plated metal screws/washers. Accepts up to 9 mm outside 4 mm inside open lug (#6, #8 or #10 lug), plus bare wire (up to 12 AWG/2.5 mm2). |
Safety Agency | Transformer is listed per UL1876 |